Electro Industries Shark 200T Especificaciones Pagina 144

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 246
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 143
Doc# E149701 A - 2
A: Shark® 200 Meter Navigation Maps
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
MAIN MENU Screen
MAIN MENU:
RSTD (blinking)
RSTE
CFG
DOWN
DOWN
MAIN MENU screen scrolls through 5 choices,
showing 3 at a time. The top choice is always the
"active" one, which is indicated by blinking the legend.
MAIN MENU:
CFG (blinking)
INFO
OPR
MAIN MENU:
OPR (blinking)
RSTD
RSTE
CONFIGURATION MODE
grid of meter settings screens with
password-protected edit capability.
See sheet 5
OPERATING MODE
grid of meter data screens.
See sheets 2 & 3
ENTER
STARTUP
sequence run once at meter startup:
2 lamp test screens, hardware information
screen, firmware version screen,
(conditional) error screens
sequence completed
RESET DEMAND MODE
sequence of screens to get password, if
required, and reset max/min data.
See sheet 4
single screen
all screens
for a display
mode
button
group of
screens
MENU
ENTER
DOWN, RIGHT
Navigation:
Editing:
Returns to previous menu from any screen in any mode
Indicates acceptance of the current screen and advances to the
next one
Navigation and edit buttons
No digits or legends are blinking. On a menu, down advances
to the next menu selection, right does nothing. In a grid of
screens, down advances to the next row, right advances to the
next column. Rows, columns, and menus all navigate circularly.
A digit or legend is blinking to indicate that it is eligible for
change. When a digit is blinking, down increases the digit
value, right moves to the next digit. When a legend is blinking,
either button advances to the next choice legend.
action taken
10 minutes
with no
user activity
Configuration Mode is not
available during a
Programmable Settings
update via a COM port.
MAIN MENU:
RSTE (blinking)
CFG
INFO
DOWN
ENTER
ENTER
ENTER
DOWN
RESET ENERGY MODE
sequence of screens to get password, if
required, and reset energy accumulators.
See sheet 4
MENU
MENU
MENU
MENU
10 minutes with no user activity
SYMBOLS BUTTONS
MAIN MENU:
INFO (blinking)
OPR
RSTD
DOWN
INFORMATION
sequence of screens to show model
information, same as STARTUP except
lamp tests omitted.
MENU
ENTER
sequence
completed
Reset Energy Mode is not
available for SHVA120,
SHAA5, or SHWA300.
Main Menu Screens (Sheet 1)
Vista de pagina 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 245 246

Comentarios a estos manuales

Sin comentarios