B: Modbus Map and Retrieving Logs
Doc# E149701 MM-7
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Description (Note 1) Format Range (Note 6) Units or Resolution Comments # Reg
Modbus Address
Hex Decimal
0BED - 0BEE 3054 - 3055 W-hours, Received, Phase C SINT32 0 to 99999999 or
0 to -99999999
Wh per energy format 2
0BEF - 0BF0 3056 - 3057 W-hours, Delivered, Phase A SINT32 0 to 99999999 or
0 to -99999999
Wh per energy format 2
0BF1 - 0BF2 3058 - 3059 W-hours, Delivered, Phase B SINT32 0 to 99999999 or
0 to -99999999
Wh per energy format 2
0BF3 - 0BF4 3060 - 3061 W-hours, Delivered, Phase C SINT32 0 to 99999999 or
0 to -99999999
Wh per energy format 2
0BF5 - 0BF6 3062 - 3063 W-hours, Net, Phase A SINT32 -99999999 to 99999999 Wh per energy format 2
0BF7 - 0BF8 3064 - 3065 W-hours, Net, Phase B SINT32 -99999999 to 99999999 Wh per energy format 2
0BF9 - 0BFA 3066 - 3067 W-hours, Net, Phase C SINT32 -99999999 to 99999999 Wh per energy format 2
0BFB - 0BFC 3068 - 3069 W-hours, Total, Phase A SINT32 0 to 99999999 Wh per energy format 2
0BFD - 0BFE 3070 - 3071 W-hours, Total, Phase B SINT32 0 to 99999999 Wh per energy format 2
0BFF - 0C00 3072 - 3073 W-hours, Total, Phase C SINT32 0 to 99999999 Wh per energy format 2
0C01 - 0C02 3074 - 3075 VAR-hours, Positive, Phase A SINT32 0 to 99999999 VARh per energy format 2
0C03 - 0C04 3076 - 3077 VAR-hours, Positive, Phase B SINT32 0 to 99999999 VARh per energy format 2
0C05 - 0C06 3078 - 3079 VAR-hours, Positive, Phase C SINT32 0 to 99999999 VARh per energy format 2
0C07 - 0C08 3080 - 3081 VAR-hours, Negative, Phase A SINT32 0 to -99999999 VARh per energy format 2
0C09 - 0C0A 3082 - 3083 VAR-hours, Negative, Phase B SINT32 0 to -99999999 VARh per energy format 2
0C0B - 0C0C 3084 - 3085 VAR-hours, Negative, Phase C SINT32 0 to -99999999 VARh per energy format 2
0C0D - 0C0E 3086 - 3087 VAR-hours, Net, Phase A SINT32 -99999999 to 99999999 VARh per energy format 2
0C0F - 0C10 3088 - 3089 VAR-hours, Net, Phase B SINT32 -99999999 to 99999999 VARh per energy format 2
0C11 - 0C12 3090 - 3091 VAR-hours, Net, Phase C SINT32 -99999999 to 99999999 VARh per energy format 2
0C13 - 0C14 3092 - 3093 VAR-hours, Total, Phase A SINT32 0 to 99999999 VARh per energy format 2
0C15 - 0C16 3094 - 3095 VAR-hours, Total, Phase B SINT32 0 to 99999999 VARh per energy format 2
0C17 - 0C18 3096 - 3097 VAR-hours, Total, Phase C SINT32 0 to 99999999 VARh per energy format 2
0C19 - 0C1A 3098 - 3099 VA-hours, Phase A SINT32 0 to 99999999 VAh per energy format 2
0C1B - 0C1C 3100 - 3101 VA-hours, Phase B SINT32 0 to 99999999 VAh per energy format 2
0C1D - 0C1E 3102 - 3103 VA-hours, Phase C SINT32 0 to 99999999 VAh per energy format 2
Block Size: 104
read-only
1003 - 1003 4100 - 4100 Phase A Current SINT16 -1800 to +1800 0.1 degree 1
1004 - 1004 4101 - 4101 Phase B Current SINT16 -1800 to +1800 0.1 degree 1
1005 - 1005 4102 - 4102 Phase C Current SINT16 -1800 to +1800 0.1 degree 1
1006 - 1006 4103 - 4103 Angle, Volts A-B SINT16 -1800 to +1800 0.1 degree 1
1007 - 1007 4104 - 4104 Angle, Volts B-C SINT16 -1800 to +1800 0.1 degree 1
1008 - 1008 4105 - 4105 Angle, Volts C-A SINT16 -1800 to +1800 0.1 degree 1
Block Size: 6
Phase Angle Block